It is quite simple device. The main chip is Vango V9821S – a single-phase energy metering SoC chip, then there is one EEPROM 24C04, optical isolation for S0, display and power supply circuitry and a display. There is no serial interface so no way how to get more data out of the device, only JTAG for programming.